EasyManuals Logo

Dell PowerEdge R760 User Manual

Dell PowerEdge R760
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #104 background imageLoading...
Page #104 background image
Figure 53. Installing a 2 x 2.5-inch rear drive module cooling fan
Next steps
1. Install the 2 x 2.5-inch rear drive module air shroud.
2. Follow the procedure listed in After working inside your system.
Removing a 4 x 2.5-inch rear drive module cooling fan
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the 4 x 2.5-inch rear drive module air shroud.
Steps
Press the orange release tab and lift the rear drive module cooling fan to disconnect from the connector on the rear drive
module.
104
Installing and removing system components

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge R760 and is the answer not in the manual?

Dell PowerEdge R760 Specifications

General IconGeneral
Form Factor2U rack server
ProcessorIntel Xeon Scalable Processors (4th Gen)
MemoryUp to 8TB DDR5
Drive BaysUp to 24 x 2.5" SAS/SATA/NVMe (HDD/SSD)
Power SupplyDual, hot-plug, redundant power supplies (800W, 1100W, 1400W options)
Network1 x 1 GbE
RAID ControllerPERC H755, H355
Operating System SupportRed Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi, Microsoft Windows Server