CAUTION: To prevent data loss, ensure that your operating system supports drive installation. See the
documentation supplied with your operating system.
Steps
1. Press the release button to open the drive carrier release handle.
2. Holding the drive carrier release handle, slide the drive carrier out of the drive slot.
NOTE: If you are not replacing the drive immediately, install a drive blank in the empty drive slot to maintain proper
system cooling.
Figure 58. Removing a drive carrier
Next steps
Replace the drive or a drive blank.
Installing the drive carrier
Prerequisites
CAUTION:
Before removing or installing a drive while the system is running, see the www.dell.com/
storagecontrollermanuals documentation for the storage controller card to ensure that the host adapter is
configured correctly to support drive removal and insertion.
CAUTION: Combining SAS and SATA drives in the same RAID volume is not supported.
CAUTION: When installing a drive, ensure that the adjacent drives are fully installed. Inserting a drive carrier
and attempting to lock its handle next to a partially installed carrier can damage the partially installed carrier's
shield spring and make it unusable.
NOTE: Ensure that the drive carrier's release handle is in the open position before inserting the carrier into the slot.
CAUTION: To prevent data loss, ensure that your operating system supports hot-swap drive installation. See the
documentation supplied with your operating system.
CAUTION: When a replacement hot swappable drive is installed and the system is powered on, the drive
automatically begins to rebuild. Ensure that the replacement drive is blank or contains data that you wish to
overwrite. Any data on the replacement drive is immediately lost after the drive is installed.
108 Installing and removing system components

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge R760 and is the answer not in the manual?

Dell PowerEdge R760 Specifications

General IconGeneral
Form Factor2U rack server
ProcessorIntel Xeon Scalable Processors (4th Gen)
MemoryUp to 8TB DDR5
Drive BaysUp to 24 x 2.5" SAS/SATA/NVMe (HDD/SSD)
Power SupplyDual, hot-plug, redundant power supplies (800W, 1100W, 1400W options)
Network1 x 1 GbE
RAID ControllerPERC H755, H355
Operating System SupportRed Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi, Microsoft Windows Server