VFD-V Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
5-54
Output Frequency
Time
ON
OFF
RUN/STOP
Startup Frequency
01-09
This parameter determines the frequency point of DC braking for both Pr. 07-02 and Pr.
07-03.
During deceleration, the drive will begin to output a DC current once the frequency reaches
the value set in this parameter.
Immediately following a RUN command, the drive will output a DC current until the output
frequency reaches the value set in this parameter.
The DC braking is commonly used to help decrease the deceleration time. For the best
stopping performance, it is recommended to use the Deceleration Time (Pr.01-13) to slow
the motor and then apply the DC brake at speeds below 25hz.
07-05 Increasing Rate of the DC Voltage
a
Factory setting 30
Settings 1~500
This parameter determines the rate of increase for the DC voltage output during the DC
injection braking function.
Output Frequency
Time
ON
OFF
RUN/STOP
Startup Frequency
01-09