Table 11
Water cooling system data
Descripon
Units 3000
1200
600/600T
1200T
1200TX
200
200T
Maximum supply pressure barg 6.9
psig 100
Necessary ow rate litres/min 7 4
4 (5
*
)
3
Maximum allowable system
dier
enal pressure
bar 5.5
Minimum necessary pres-
sure dierenal across sup-
ply and return
bar 0.75 0.75 1.0 0.75
Supply temperature range °C 5 to 30
Water type Treated or non-corrosive industrial
Maximum parcle size
mm
2
0.03
Acidity pH 6.5 t
o 8.0
Hardness (< 100 mg of Ca-
CO
3
per litr
e)
ppm of CaCO
3
< 100
Resisvity ohm-cm
1 k £ r £ 1000 k
Materials in contact with
c
ooling w
ater
Stainless steel
and uoroelas-
tomer
Stainless steel, Nitrile, PTFE and uoroe-
lastomer
Water inlet connecon 3/8 inch BSP male quick connector
Water outlet connecon 3/8 inch BSP female quick connector
*
For iXM1200 TX variants, if connuous operaon is required with 60 slm (Air) or more
at the pumped gas inlet, 5 l/min is recommended. Please contact us for more
informaon.
3.8 Heater data
Table 12
TX variant heater data
Descripon
Units Rang
Exhaust heater control temperature °C 160
Exhaust heater power consumpon
iXM1200TX W 110
T
ypical booster heater control temperature °C 85
Typical booster heater power consumpon
iXM1200TX kW 1.2
10/2020 - ©Edwards Limited
Page 22M56635880_D
M56635880_D - Technical data

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards iXM Series and is the answer not in the manual?

Edwards iXM Series Specifications

General IconGeneral
BrandEdwards
ModeliXM Series
CategoryWater Pump
LanguageEnglish

Related product manuals