4.4 Install the system
Requir
ements to secure the system in place to prevent unwanted movement (for
example, during an earthquake):
▪ A minimum of 2 seismic brackets are necessary to secure the pump.
▪ The seismic brackets (Figure: Front view of the system) are designed to withstand a
level 4 earthquake in a ground oor installaon (available as an accessory). Refer
to Accessories on page 93.
▪ There are seismic mounng points along the sides of the pump. If you have to
consider space constraints, there are alternave seismic mounng points on the
front and rear bulkhead.
▪ The system can be aached to the oor with applicable bolts or studs (not
supplied) through the 17.5 mm diameter hole in the seismic brackets.
▪ If vibraon transmission to the oor is a possible problem, aach vibraon
isolators (not supplied) between the seismic brackets and the bolt or stud.
▪ Make sure that the bolt spacing is sucient for the oor strength and expected
loads.
▪ The system has mounng points to aach four seismic brackets as shown in view A
of Figure: Reduce the eecve system footprint. On smaller systems, two brackets
can hold the system during an earthquake. The smaller systems can be aached as
shown in view B of Figure: Reduce the eecve system footprint, to decrease the
eecve system footprint. if necessary, view C of Figure: Reduce the eecve
system footprint and Figure: Reduce the eecve system footprint iXM3000 also
shows an alternave way of reducing the system’s footprint, where the seismic
brackets are securing the system from the front and back. Refer to Accessories on
page 93 to select the correct seismic bracket kit for the system and for informaon
about the systems which can be held with only two brackets.