The system includes provision for venlaon
extracon and secondary
containment of oil and water leaks. Remove all the accidental overows or spills
immediately to avoid risk of slips.
Obey all naonal and local rules and safety regulaons when you install the dry
pumping system. Refer the Vacuum Pump and Vacuum System Safety manual
(publicaon number P40040100) before you pump hazardous materials.
Put and secure cables, hoses and pipework during installaon to avoid possible trip
hazard.
Make sure that the installaon area is clean and free from debris and
contaminaon, such as oil, before you put the pump in posion.
For the system to perform to specicaon, give appropriate facilies as given in this
manual.
4.2 Unpack and inspect
WARNING: HEAVY OBJECT
Risk of injury or damag
e to equipment. Use suitable liing equipment to move the
pump. Aach the liing equipment to the liing eye. Do not use loose slings. Take
care when you move the pump into posion, its mass may make it dicult to slide.
The fan cowl is shaped to provide a handhold for posioning the pump. Do not li
the pump using this handhold.
CAUTION: ENVIRONMENTAL SAFETY
Risk of damage t
o environment. Obey all naonal and local legislaon concerning the
impact of the pump on the environment when you install or remove the pump.
The pump is supplied xed by metal brackets to a wooden pallet with a cardboard
surround. These metal brackets should be removed and retained.
To unpack the pump, do the steps that follow:
1. Be careful when you unpack the pump to prevent the excessive shocks. The
excessive shocks can damage the bearings and decrease the life of the pump. The
pump is supplied with sealed inlets and outlets to prevent the entry of dust and
vapour.
2. Do not remove the seals unl the pump is ready t
o be installed on the vacuum
system.
3. Open the cardboard box from the top, remove any excess packaging as required
and remove the pump from the pallet at the xing points using suitable liing
equipment.
4. If the pump is damaged, nofy your supplier and the carrier in wring within three
days. Give the supplier and the carrier the informaon that follows:
Item number of the pump
Order number
Supplier's invoice number
5. Retain all packing materials for inspecon.
6. Do not use the pump if it is damaged.
10/2020 - ©Edwards Limited
Page 26M56635880_D
M56635880_D - Inst
allaon

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards iXM Series and is the answer not in the manual?

Edwards iXM Series Specifications

General IconGeneral
BrandEdwards
ModeliXM Series
CategoryWater Pump
LanguageEnglish

Related product manuals