Fault Alarm 184.10 - DP Low Speed
Cause The dry pump speed is very low. The rotor is possibly locked.
Remedy Cycle the power to the pump and aempt t
o restart. If this fails, contact us.
Fault Alarm 186.01 - DP INV zzzzzzzzzzzzz
Cause DP Inverter gives alarm code xxxx yyyy / Diagnosc registers aaaa bbbb.  is the
inverter fault count.
Remedy Refer to Inverter warnings and alarms on page 83 for more informaon.
Fault Alarm 186.01 - DP Not Running
Cause Dry Pump Inverter will not start up when requested.
Remedy Examine inverter fault history.
Fault Alarm 186.13 - No DP Inv Comms
Cause The pump controller cannot communicate with the dry pump inverter during
st
art up checks.
Remedy Examine the wiring between the pump controller and the dry pump inverter.
8.2.3 Alarm condions
CAUTION: LOSS OF WARRANTY
If 'Run 'l crash' is select
ed, the pump(s) can get damaged and all the warranes are
invalidated on the system equipment.
Normally, if an alarm condion exists, the control system will shut down the system.
For pumping systems which has a dry pump and booster combinaon, some alarms will
cause only the booster to stop and not the full system.
Note:
If required 'Run 'l crash' operaon can be reques
ted. In this mode of operaon most
alarm condions will be ignored and the pump(s) will connue to operate. For safety
reasons, some alarms cannot be overridden and the system will automacally shut down
even if 'Run 'l crash' has been selected. Refer to Table: Alarm acons.
'Run 'l crash' is automacally reset to 'o ' when the electrical supply is removed.
The Tool Interface overrides the 'Run 'l crash' state selected if it has control of the
pump.
10/2020 - ©Edwards Limited
Page 79M56635880_D
M56635880_D - Fault nding

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards iXM Series and is the answer not in the manual?

Edwards iXM Series Specifications

General IconGeneral
BrandEdwards
ModeliXM Series
CategoryWater Pump
LanguageEnglish

Related product manuals