DVC6000f Series
Errata Sheet
April 2007
3
NEPSI Approvals
Page 3, 4, and 5 of this errata sheet contain
instructions for safe use in in hazardous locations
and nameplates (see figure 1) for NEPSI approvals.
Refer to the DVC6000f Series FIELDVUE
R
Digital
Valve Controller Instruction Manual Form 5774,
dated March 2006 or the DVC6000f Series
FIELDVUE
R
Digital Valve Controller Quick Start
Guide Form 5778, dated December 2005, for all
other information and instructions pertaining to the
DVC6000f digital valve controller.
Special Instructions for Safe Use and
Installations in Hazardous Locations
Certain nameplates may carry more than one
approval, and each approval may have unique
installation requirements and/or conditions of safe
use.
After reading and understanding these special
special conditions of use, proceed with standard
installation procedures as found in the quick start
guide or instruction manual.
WARNING
Failure to follow these conditions of
safe use could result in personal injury
or property damage from fire or
explosion, or area re-classification.
NEPSI Intrinsic Safety
Notes for Safe Use of the Certified Product
DVC6000f series digital valve controllers
(designated as controller hereafter) have been
proved to be in conformity with the requirements
specified in the national standards GB3836.1-2000
and GB3836.4-2000 through inspections conducted
by National Supervision and Inspection Centre for
Explosion Protection and Safety of Instrumentation
(NEPSI). The Ex marking for the products is Ex ia II
CT6/T5/T4, and their Ex certificate number is
GYJ06280. When using the product, the user should
pay attention to the items stated below:
1. The correlation of approved DVC6000f Series
digital valve controllers in specific product type, Ex
marking and operating ambient temperature this
time is as follows:
Mounting Style
Product
Type
Ex Marking
Ambient
Temperature
Integral Mounting
DVC6010f
DVC6020f
DVC6030f
Ex ia II CT6
40_C to
+75_C
Ex ia II CT5
40_C to
+80_C
Separate
Mounting
Main Unit DVC6005f
Ex ia II CT6
40_C to
+75_C
Ex ia II CT5
40_C to
+80_C
Feedback
Unit
DVC6015 Ex ia II CT6
60_C to
+80_C
DVC6025 Ex ia II CT5
60_C to
+95_C
DVC6035 Ex ia II CT4
60_C to
+125_C
2. The enclosure of the controller provides a
grounding terminal, and the user should install a
reliable grounding wire connected to it when
mounting and using the controller.
3. The values for intrinsically safe parameters and
maximum internal equivalent parameters of the
controller are as follow:
Max Input
Voltage
Ui (V)
Max Input
Current
Ii (mA)
Max Input
Power
Pi (W)
Max Internal
Equivalent Parameter
Ci (nF) Li (mH)
24 226 1.4 5 0
17.5 380 5.32 5 0
4. As a main unit of a separate design product, the
values for intrinsically safe output parameters of
DVC6005f are as follows:
Max Output
Voltage
Uo (V)
Max
Output
Current
Io (mA)
Max
Output
Power
Po (mW)
Max Equivalent
Parameter allowed
Co (mF) Lo (mH)
8.6 2.3 5 8.2 100
5. While the controller forms an intrinsically safe
explosion protection system together with an
associated equipment, the following requirements
must be met: Uo vUi, Io vIi, Po vPi, Co wCi + Cc,
Lo wLi + Lc.
Note
Where Cc and Lc represent
distributing capacitance and
inductance of the connecting cable
respectively.
6. The connection cable between the product and
associated equipment should be a cable with

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Fisher Fieldvue DVC6020f and is the answer not in the manual?

Emerson Fisher Fieldvue DVC6020f Specifications

General IconGeneral
BrandEmerson
ModelFisher Fieldvue DVC6020f
CategoryController
LanguageEnglish

Related product manuals