EasyManuals Logo
Home>Epiroc>Cutter>ER-L Series

Epiroc ER-L Series User Manual

Epiroc ER-L Series
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #83 background imageLoading...
Page #83 background image
Safety and operating instructions
© Anbaufräsen PC GmbH | 3390 5221 01 | 2020-09-07
Original Instructions
83
13.3 Hydraulic settings (explanation for following diagrams)
Q = Oil flow rate (l/min)
n = Cutter drum revolution (rpm)
p = Operating pressure (bar)
M = Torque at cutter drum (Nm)
P = Recommended operating setting (see technical data)
1 = Upper limit of the recommended power range:
The drum cutter must not be operated simultaneously at maximum operating pressure and maximum oil flow rate, other-
wise the permissible nominal power is exceeded. The drum cutter must be operated within the recommended power
range.
The higher the operating pressure the higher the cutting force and torque.
The higher the oil flow the higher the rotational speed and pick speed.
2 = maximum permissible motor load:
The combination of oil flow rate and operating pressure must not exceed the nominal power of the drum cutter.
The nominal power is checked according to the following formula:
Nominal power (kW) = p (bar) x Q (l/min) / 600

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epiroc ER-L Series and is the answer not in the manual?

Epiroc ER-L Series Specifications

General IconGeneral
BrandEpiroc
ModelER-L Series
CategoryCutter
LanguageEnglish