EasyManuals Logo
Home>Fronius>Portable Generator>MagicWave 3000

Fronius MagicWave 3000 User Manual

Fronius MagicWave 3000
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #104 background imageLoading...
Page #104 background image
Special 2-step
Special 2-step mode for HF ignition after touching the workpiece
Unit -
Setting range OFF / 1
Factory setting OFF
Ignition sequence, when the STS parameter is set to 1:
- Touch the workpiece with the tungsten electrode
- The short circuit detection on the power source is triggered
- Lift the tungsten electrode off
- After 300 ms the gas pre-flow time begins
- HF ignition is initiated
- End of welding due to arc break
Ign. delay
Ignition delay
Delayed ignition with immediate high frequency start
Unit s
Setting range OFF / 0.1 - 1
Factory setting OFF
If a time value is set for the welding parameter "Ign. delay", the welding arc ignition is
delayed by this time value: Press the torch trigger - high frequency is activated for the
specified duration - the welding arc is ignited
104