Special 2-step
Special 2-step mode for HF ignition after touching the workpiece
Unit -
Setting range OFF / 1
Factory setting OFF
Ignition sequence, when the STS parameter is set to 1:
- Touch the workpiece with the tungsten electrode
- The short circuit detection on the power source is triggered
- Lift the tungsten electrode off
- After 300 ms the gas pre-flow time begins
- HF ignition is initiated
- End of welding due to arc break
Ign. delay
Ignition delay
Delayed ignition with immediate high frequency start
Unit s
Setting range OFF / 0.1 - 1
Factory setting OFF
If a time value is set for the welding parameter "Ign. delay", the welding arc ignition is
delayed by this time value: Press the torch trigger - high frequency is activated for the
specified duration - the welding arc is ignited
104