TIG welding
Safety
WARNING!
Danger from incorrect operation.
Possible serious injury and damage to property.
▶
Do not use the functions described here until you have read and completely under-
stood these Operating Instructions.
▶
Do not use the functions described here until you have fully read and understood all
of the Operating Instructions for the system components, in particular the safety
rules!
WARNING!
An electric shock can be fatal.
If the power source is connected to the mains electricity supply during installation, there
is a high risk of very serious injury and damage.
▶
Before carrying out any work on the device make sure that the power source mains
switch is in the "O" position
▶
Before carrying out any work on the device make sure that the power source is
unplugged from the mains
Welding paramet-
ers: display and
navigation
The TIG welding parameters are shown as soon as the 2-step or 4-step mode is selec-
ted.
Use the left and right arrow keys to navigate within the welding parameters.
Welding paramet-
ers for TIG
Starting current, 2-step mode
Starting current, 4-step mode
Unit % (of main current)
Setting range 30 - 200 AC, 0 - 200 DC
Factory setting 35 AC, 50 DC
IMPORTANT! The starting current is saved separately for the TIG AC welding and TIG
DC welding modes.
51
EN