TransTig 4000
Comfort MV
Mains voltage 3 x 200 - 240 V
3 x 380 - 460 V
Mains voltage tolerance ± 10%
Grid frequency 50/60 Hz
Mains fuse protection (slow-blow) 63 / 35 A
Mains connection
1)
Restrictions possible
Primary continuous power (100% D.C.
2)
)
11.5 kVA
Cos phi 0.99
Welding current range
TIG 3 - 400 A
Electrode 10 - 400 A
Welding current at
10 min/40 °C (104 °F) 40% D.C.
2)
-
10 min/40 °C (104 °F) 45% D.C.
2)
400 A
10 min/40 °C (104 °F) 60% D.C.
2)
360 A
10 min/40 °C (104 °F) 100% D.C.
2)
300 A
Open circuit voltage 86 V
Working voltage
TIG 10.1 - 26.0 V
Electrode 20.4 - 36.0 V
Striking voltage (U
p
) 9.5 kV
The arc striking voltage is suitable for manual operation.
Degree of protection IP 23
Type of cooling AF
Insulation class F
EMC device class
(in accordance with EN/IEC 60974-10)
A
Dimensions L/W/H (with handle) 625 / 290 / 475 mm
24.6 / 11.4 / 18.7 in.
Weight 42.0 kg
92.6 lb.
Mark of conformity S, CE, CSA
Idle state power consumption at 400 V 40.5 W
Power source efficiency at 400 A / 36.0 V 89%
TransTig 5000
Comfort
Mains voltage 3 x 400 V
Mains voltage tolerance ± 15%
Grid frequency 50/60 Hz
214

Table of Contents

Other manuals for Fronius MagicWave 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius MagicWave 3000 and is the answer not in the manual?

Fronius MagicWave 3000 Specifications

General IconGeneral
BrandFronius
ModelMagicWave 3000
CategoryPortable Generator
LanguageEnglish

Related product manuals