Start-up
Safety
WARNING!
An electric shock can be fatal.
If the device is plugged into the mains during installation, there is a high risk of very seri-
ous injury and damage.
Only carry out work on the device if the mains switch is in the "O" position.
Only carry out work on the charger when it has been disconnected from the mains
supply.
WARNING!
Danger of electrical current due to electrically conductive dust in the device.
This can result in severe personal injury and damage to property.
Only operate the device if an air filter is fitted. The air filter is a very important safety
device for achieving IP 23 protection.
Remarks on the
cooling unit
We recommend using a cooling unit for the following applications and situations:
- JobMaster TIG welding torch
- Robot welding
- Hosepacks over 5 m long
- TIG AC welding
- In general, where welding is performed in higher power ranges
The cooling unit is powered from the power source. The cooling unit is ready for opera-
tion when the mains switch of the power source is in the "I" position.
More information on the cooling unit can be found in the operating instructions for the
cooling unit.
General This section describes how to commission the power source:
- for the main TIG welding application
- with reference to a standard configuration for a TIG welding system
The standard configuration consists of the following system components:
- Power source
- TIG manual welding torch
- Pressure regulator
- Gas cylinder
Connecting the
gas cylinder
WARNING!
If gas cylinders topple over, there is a risk of very serious injury and damage.
Place gas cylinders on a solid, level surface in such a way that they remain stable
Secure gas cylinders to prevent them from toppling over: fix the safety strap at the
same height as the top part of the cylinder
Never fix the safety strap around the neck of the cylinder
Follow the gas cylinder manufacturer's safety instructions.
40

Table of Contents

Other manuals for Fronius MagicWave 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius MagicWave 3000 and is the answer not in the manual?

Fronius MagicWave 3000 Specifications

General IconGeneral
BrandFronius
ModelMagicWave 3000
CategoryPortable Generator
LanguageEnglish

Related product manuals