MagicWave
2500 / 3000 Com-
fort
(1)
(2)
(3)
(4)
(5)
MagicWave 2500 / 3000 Comfort - front
(6)
(7)
(8)
MagicWave 2500 / 3000 Comfort - rear
No
.
Function
(1) Grounding (earthing) cable connection
for connecting the grounding (earthing) cable
(2) LocalNet connection
standardised connection socket for system add-ons (e.g. remote control, Job-
Master TIG welding torch, etc.)
(3) Handle
(4) Torch control connection
- for connecting the control plug of a conventional welding torch
- input for the collision protection signal when a robot interface or field bus
coupler is connected
(5) Welding torch connection
for connecting:
- the TIG welding torch
- the electrode cable for manual metal arc welding
(6) Shielding gas connection
(7) Mains cable with strain relief device
(8) Mains switch
for switching the power source on and off