Cause: Emergency Stop - safety circuit
is open
Remedy: Contact After-Sales Service
Cause: The VRD (Voltage Reduction
Device) function has interrupted
the welding process
Remedy: Contact After-Sales Service
Service codes
displayed in con-
junction with the
digital gas con-
trol option
Cause: The gas watchdog option has
detected that there is no gas
pressure
Remedy: Check protective gas shield
supply, connect new gas cylin-
ders or gas cylinder valves/
open gas pressure regulator
Displayed Ser-
vice codes in
conjunction with
cold wire-feed
unit
The following abbreviations are used for the service codes shown in conjunction with
cold wire-feed units:
KD = Cold wire-feed unit
PPU = Push-pull unit
vDmin = minimum wire feed speed
vDma
x
= maximum wire feed speed
Cause: The external supply voltage has
dropped below the tolerance
limit
Remedy: Check the external supply
voltage
Cause: Wire-feed unit motor is sticking
or defective
Remedy: Check or replace the wire-feed
unit motor
189
EN

Table of Contents

Other manuals for Fronius MagicWave 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius MagicWave 3000 and is the answer not in the manual?

Fronius MagicWave 3000 Specifications

General IconGeneral
BrandFronius
ModelMagicWave 3000
CategoryPortable Generator
LanguageEnglish

Related product manuals