Wire withdrawal
Unit mm in.
Setting range OFF / 1 - 50 OFF / 0.04 - 1.97
IMPORTANT! Wire withdrawal prevents the welding wire from burning at the end of
welding. Before the welding current is switched off, the wire is withdrawn by the set
value. A prerequisite for this function is that the arc has ignited.
Wire threading
Feeder inching speed
Unit m/min ipm.
Setting range 1.0 - max. 39.37 - max.
Adjustable rod
electrode para-
meters
Main current
Unit A
Setting range MW 2200 Comfort 10 - 180
MW 2500 Comfort 10 - 250
MW 3000 Comfort 10 - 300
MW 4000 Comfort 10 - 400
MW 5000 Comfort 10 - 500
TT 2200 Comfort 10 - 180
TT 2500 Comfort 10 - 250
TT 3000 Comfort 10 - 300
TT 4000 Comfort 10 - 400
TT 5000 Comfort 10 - 500
Arc-force dynamic
In order to obtain optimum welding results, it will sometimes be necessary to set the
arc-force dynamic function.
Unit % (of main current)
Setting range 0 - 100
0 soft, low-spatter arc
100 harder, more stable arc
Functional principle:
at the instant of droplet transfer or in the event of a short circuit, there is a momentary
rise in amperage. In order to obtain a stable arc, the welding current is temporarily
increased. If the rod electrode threatens to sink into the weld pool, this measure pre-
vents the weld pool solidifying, as well as preventing more prolonged short circuiting of
the arc. This largely prevents the rod electrode from sticking.
Jobslope
For changing to another job during welding. Jobslope is the time that it takes for the
welding current to adjust seamlessly from the present job to the next.
Unit s
Setting range Off / 0.1 - 9.9
NOTE!
Switching over from one job to the next without interrupting welding is only pos-
sible with a JobMaster TIG welding torch, robot interface or field bus.
Starting current
Unit % (of main current)
Setting range 30 - 200 AC, 0 - 200 DC
159
EN