only with MagicWave for the manual metal arc AC welding process
Unit 1
Setting range -5 - +5
Factory setting 0
-5: highest fusing power, lowest cleaning action
+5: highest cleaning action, lowest fusing power
Preparation
1
Set up and install the power source in accordance with the welding job
2
Plug in the mains plug
CAUTION!
Risk of injury and damage from electric shock.
As soon as the mains switch is in the "I" position, the tungsten electrode of the welding
torch is live.
▶
Ensure that the tungsten electrode does not touch any persons or electrically con-
ductive or earthed parts (e.g. housing, etc.).
3
Move the mains switch to the "I" position
The starting sequence with the Fronius logo, current firmware version and Fronius
internet address is displayed for approx. 1 second:
75
EN