No. Function
(15) HF (high frequency) ignition indicator
lights up when the HF ignition welding parameter has been set to an inter-
val for the high frequency pulses
TransTig
Comfort control
panel
(3)
(11)
(6)
(8)
(1)
(10)
(9)
(4)
(13)
(12)
)7()5()2(
(14)
No. Function
(1) Pulse indicator
lights up when the F-P set-up parameter has been set to a pulse frequency
(2) Spot welding indicator
lights up when the SPt set-up parameter has been set to a spot welding
time
(3) Cold wire-feed unit indicator
lights up when a cold wire-feed unit is connected
(4) Display
(5) Tacking indicator
lights up when the tAC set-up parameter has been set to a period of time
(6) Electrode overload indicator
lights up if the tungsten electrode is overloaded
See section on TIG welding in Chapter "Welding mode" for more informa-
tion on the electrode overload indicator.
(7) Keylock indicator
lights up when the keylock is activated
(8) Right arrow key
for navigating in the menu
(9) Mode button
for selecting the mode
2-step mode
4-step mode
Manual metal arc welding
27
EN

Table of Contents

Other manuals for Fronius MagicWave 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius MagicWave 3000 and is the answer not in the manual?

Fronius MagicWave 3000 Specifications

General IconGeneral
BrandFronius
ModelMagicWave 3000
CategoryPortable Generator
LanguageEnglish

Related product manuals