Procedure with TransTig power source for switching from MMA DC- welding to MMA DC
+ welding:
a) Move the mains switch to the "O" position
b) Disconnect the mains plug
c) Reconnect the electrode holder and the grounding cable to the opposite current
sockets (i.e. swap them over)
d) Plug in the mains plug
CAUTION!
Risk of injury and damage from electric shock.
As soon as the mains switch is in the "I" position, the rod electrode in the electrode
holder is live.
▶
Make sure that the rod electrode does not touch any persons or electrically con-
ductive or earthed parts (e.g. the housing, etc.)
e) Move the mains switch to the "I" position
The starting sequence with the Fronius logo, current firmware version and Fronius
internet address is displayed for approx. 1 second:
3
Use the right arrow key to select the relevant welding parameters
4
Use the adjusting dial to set the selected welding parameter to the required value
5
If necessary, additional welding parameters can be set in the Setup menu:
- Press the Menu key
The relevant menu is displayed:
- Use the adjusting dial to select the desired Setup menu
- Open the selected Setup menu by pressing the adjusting dial
- Use the adjusting dial to select the welding parameter
- To change the welding parameter press the adjusting dial
- Change the welding parameter value using the adjusting dial
- Press the adjusting dial
- Exit the Setup menu
NOTE!
All welding parameter set values that have been set using the adjusting dial
remain stored until the next time they are changed.
This applies even if the power source was switched off and on again in the interim.
6
Start welding
67
EN