SPECIAL EQUIPMENT (OPTIONAL)
104 OI 248 (EN) REV6 /REV0
12.2.4 Exchange of FlexLink Gas Connections
The flexible metal hose is fitted for sealing purposes with a sealing
set consisting of a plastic bushing (1.1) flanked by two O-rings
(1.2). For the sealing set to fit properly on the end of the flexible
metal hose (1), two corrugation valleys (2) must remain uncovered.
Two locking plates (3) offset radially from one another prevent the
sealing set from sliding when inserted into the sealing area of the
coupling (4). A secure fit of the flexible metal hose (1) is ensured by
screwing on the locking plates (3).
1 Flexible metal hose 1x
1.1 Plastic bushing 1x
1.2 O-ring 2x
2 Corrugation valley -
3 Locking plate 2x
4 Coupling (filling connection) 1x
5 Screw 2x
1
5
4
3
1.2
1.1
1.2
2
2
FLEX-SCHLAUCH-AUFBAU