Ch.8127
——— Parameters lists ———
8. PARAMETERS LIST
Explanation of tables:
White text on black background Menu/submenu
White text on black background Menu does not exist in the keypad
in brackets
Fields with gray background Function not accessible via keypad. The status of the correspond-
ing parameter is only displayed.
[FF] in the Parameter column Dimension based on the factor function
"No." column Parameter number (decimal). The value 2000H (= decimal
8192) must be added to the number given in the “No.” column
in order to obtain the index to access the parameter via Bus ,
serial line or Opt2 (APC card). The parameters in the Drivecom
group can be accessed using the format and index specified in
the DRIVECOM power transmission profile (#21).
"Format" column Internal parameter format:
I= Integer (Example: I16 = Integer 16 bit)
U = Unsigned (Example: U32 = unsigned 32 bit)
Float = Floating point
"Value" column Minimum, maximum and factory parameter values.
S = set value depending on the size of the device.
F = set value depending on the Flt 100 mF [303] parameter
“Factory” column S = factory set value depending on the size of the device.
“Keypad” column √ = Parameter available via keypad
“RS485/BUS/Opt2-M" column Parameter available via RS485, field Bus or via the APC Card
(Low priority) manual communication (see the APC Card user manual)
The numbers indicate what has to be sent via interface line in order
to set the single parameters.
“Term.” column Parameter addressable to one of the analog or digital input/output
terminals.