Introduction | Remote Desktop Manager (option 133)
2
HEIDENHAIN | TNC 640 | Conversational Programming User's Manual | 10/2017
127
Setting Meaning Input
Release USB mass memory
Not advisable with this connection
Calculator
Host name or IP address of the external computer. In the recom-
mended configuration of the IPC 6641, the IP address 192.168.254.3
is used
Required
User name
User name with which the connection should be logged on Required
Password
Password for connecting to the VNC server Required
Windows domain:
Domain of the target computer, if required Optional
Max. waiting time (seconds):
When the control shuts down, it commands the Windows comput-
er to shut down. Before the control displays the message You may
switch off now, it waits for <Timeout> seconds. If the Windows
computer is switched off before the <Timeout> seconds have
expired, the control stops waiting.
Required
Force
If Force is not selected, Windows waits up to 20 seconds. This
delays the shutdown process or the Windows computer is switched
off before Windows has shut down.
Required
Restart
Reboot the Windows computer. Required
Run during restart
Reboot the Windows computer when the control reboots. Effective
only if the control is rebooted using the shutdown icon at the bottom
right in the taskbar or if a reboot is initiated as a result of a change in
the system settings (e.g. network settings).
Required
Run during switch-off
The Windows computer is switched off when the control is shut
down (no reboot). This is the standard scenario. The END key will
then no longer trigger a reboot, either.
Required
Entries in the Advanced
options area
Available only to authorized specialists Optional
Starting and stopping the connection
Once a connection has been configured, it is shown as an icon in
the Remote Desktop Manager window. Click the connection icon
with the right mouse key to open a menu in which the display can
be started and stopped.
Use the right DIADUR key on the keyboard to change to the third
desktop and back to the control interface. You can also use the task
bar to get to this desktop.
If the desktop of the external connection or the external computer
is active, all inputs from the mouse and the keyboard are
transmitted there.
When the HEROS 5 operating system is shut down, all
connections are canceled automatically. Please note, however, that
only the connection is canceled, whereas the external computer or
the external system is not shut down automatically.
Further information: "Shutting down or rebooting an external
computer", page 126

Table of Contents

Other manuals for HEIDENHAIN TNC 640

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HEIDENHAIN TNC 640 and is the answer not in the manual?

HEIDENHAIN TNC 640 Specifications

General IconGeneral
Control TypeCNC
AxesUp to 18 axes
InterfacesEthernet, USB, RS-232
Spindle ControlYes
PLCIntegrated
StorageSSD
Programming LanguagesDIN/ISO
Safety Featuressafety functions according to EN ISO 13849-1
DimensionsVaries based on configuration
WeightVaries based on configuration
Operating SystemWindows

Related product manuals