{3} End the command.
3.1.2 Operator Configuration
The programming command of operator configuration is shown below.
001 *2 1234 #
1 2 3 4
{1} Operator Programming Address: 001016.
{2} User Permission: 12 permissions. For details, please refer to the
following table.
No.
Permission
No.
Permission
1
Arming
No Arming Report
Unavailable Bypass
2
Arming/Disarming
No Disarming Report
Unavailable Bypass
3
Arming/Disarming
No Arming/Disarming
Report,
Unavailable Bypass
4
Arming
Arming Report
Unavailable Bypass
5
Disarming
Disarming Report
Unavailable Bypass
6
Arming/ Disarming
Arming/Disarming Report
Unavailable Bypass
7
Arming
No Disarming Report
8
Disarming
No Arming/Disarming
Report
9
Arming/Disarming
No Arming/Disarming
Report
Bypass
*0
Arming
Arming Report
Bypass
*1
Disarming
*2
Arming/Disarming

Table of Contents