Control Panel User Manual
29
{3} Specified the username and password, the length of user name
should be in the range of 2 to 5 characters.
{4} End the command.
The username and password cannot be empty. If the password is configured as
0, the user will be deleted. The password of 00, 000, 0000, or 00000 all signify
of deleting the user.
The default password of the main operator is 1234 with the permission of 2.
The default permission of other operators is 6.
3.1.3 Zone Parameters Configuration
The parameters of zone include zone response time, zone arming type, linked
local alarm output, linked siren output. The detailed command is shown
below.
201 2 5 0 1 0 1 0 0 1 1 #
1
2 4 63 5
87
9
10
11 12
{1} Zone Parameters Programming Address: 201208/216
For 8-zone network security control panel , the zone parameters
programming address is 201~208.
For 16-zone network security control panel, the zone parameters
programming address is 201~216.
{2} Zone Response Time. The 4 kinds of zone response time is shown as
follows.
Disarming Report
Bypass
Arming/Disarming Report
Bypass

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-19A08-F/Kx and is the answer not in the manual?

HIKVISION DS-19A08-F/Kx Specifications

General IconGeneral
BrandHIKVISION
ModelDS-19A08-F/Kx
CategoryControl Panel
LanguageEnglish

Related product manuals