145
Configuring temperature alarm thresholds for a
member device
When the temperature of the device reaches a threshold, the device generates alarms.
The temperature alarm thresholds include the low-temperature threshold, high-temperature warning
threshold, and high-temperature alarming threshold.
If the temperature is lower than the low-temperature limit, the device logs the event and outputs the
log information and trap information for users.
If the temperature reaches the high-temperature warning threshold, the device logs the event and
outputs the log information and trap information for users.
If the temperature reaches the high-temperature alarming threshold, the device not only repeatedly
outputs the log information and trap information in the terminal display, but also alerts users
through the LED on the device panel.
While you are cooling down the device in response to a high-temperature alarm, the temperature of the
device might fluctuate in a narrow range near a high-temperature threshold. The device can suppress
frequent alarms caused by some fluctuations. After issuing a high-temperature alarm, the device does not
issue another alarm if the temperature is in the range of (thresholdoffset) °C to threshold °C. The offset
might be 3°C or 5°C, depending on the device model.
Follow these steps to configure temperature alarm thresholds for a member device:
To do… Use the command…
Remarks
Enter system view system-view
Configure temperature alarm
thresholds for a member
device
temperature-limit slot slot-number
hotspot sensor-number lowlimit
warninglimit [ alarmlimit ]
Optional
By default, the temperature alarm
thresholds follow the specifications listed
in Table 13.
The alarming threshold must be higher
than the warnin
g threshold.
Table 13 Default temperature alarm thresholds for a device
Device Sensor
Warnin
g
limit
Alarmin
g
limit
S5120-28P-PWR-SI/
S5120-28P-HPWR-SI
1 85 95
2 115 125
S5120-52P-SI 1 90 95
S5120-20P-SI/S5120-28P-SI 1 85 95
S5120-9P-SI 1 98 105
S5120-9P-PWR-SI
1 88 95
2 115 125
S5120-9P-HPWR-SI
1 75 90
2 115 125