Operation
Powermax45 XP Operator Manual 809240 55
2. Press-and-hold the Mode
button with one hand. Turn
the adjustment knob to the
desired gas pressure with the
other hand. In this example,
we turned down the gas
pressure to 35 psi.
As you manually
adjust the gas
pressure, the AMPS
LED turns off, and the
2-digit display
changes from
amperage to gas
pressure, as follows:
CSA models: The gas pressure displays in psi by default.
CE/CCC models: The gas pressure displays in bar by default.
You can change the display values for gas pressure. See page 57.
3. Release the Mode button.
After you release the
Mode button, the
AMPS LED
illuminates again, and
the 2-digit display
changes from gas
pressure back to
amperage.
The selected mode LED blinks to let you know that the gas pressure has been manually
adjusted. It continues to blink until you reset the pressure.
To view the gas pressure setting again, repeat step 2 above, or enter gas test mode.
See Run a gas test on page 149.
Press-and-hold the button while turning the knob.
ARC WELDING SUPPLIES - 07 847 7870