12.3 NTC resistances
NTC 12 kOhm
T [°C] R [Ω] T [°C] R [Ω] T [°C] R [Ω] T [°C] R [Ω]
-15 76020 15 18300 45 5522 75 1994
-10 58880 20 14770 50 4609 80 1717
-5 45950 25 12000 55 3863 85 1467
0 36130 30 9805 60 3253 90 1266
5 28600 35 8055 65 2752 95 1096
10 22800 40 6653 70 2337 100 952
12.2 Product Fiche according to CELEX-32013R0811, Appendix IV
Supplier
Intergas Heating Ltd
Unit 2
Easter Park
Worcester Road
Kidderminster
DY11 7AR
Type designation Symbol Unit
Intergas Xclusive
24 30 36
Seasonal energy eiciency class for
room heating
- - A A A
Nominal heat output (capacity) P
rated
kW 18 23 27
Seasonal energy eiciency class for
room heating
s
% 93 93 93
Annual energy use Q
HE
GJ 38 48 58
Noise level L
WA
dB 56 56 58
Domestic hot water capacity profile - - L XL XL
Energy eiciency class for water
heating
- - A A A
Domestic hot water eiciency
WH
% 85 86 87
Annual electricity use AEC kWh 13
17
15
Annual fuel use AFC
GJ 11 18 17
IMPORTANT
► Before installation, read the installation manual and the operation instructions.
► This appliance is not intended for use by individuals (included children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
supervision of or instruction concerning the use of the appliance is given. Children shall not
play with the appliance. Cleaning and user maintenance shall not be undertaken by children.
► The boiler and system must be inspected annually by an qualified Gas Safe registered
engineer and cleaned if necessary. See §11 for the annual servicing procedure.
► The boiler outer casing must only be cleaned with a damp cloth. Do not use aggressive
scrubbing, agents or solvents.