9
3.3 Data plate
3.2 Operation
The Intergas Xclusive is a modulating high eiciency boiler. This means
that the output is adjusted according to the desired heating capacity.
Two separate copper circuits are infused within the aluminium
Bithermic heat exchanger.
The boiler has a printed circuit board with microprocessor control, this
allows constant calculations to take place during any demand for either
heating or hot water, these calculations are based on many factors and
measuring points within the boiler.
The microprocessor manages and takes control of the modulating
output, ensuring optimum eiciency is maintained at all times during
production.
******
-yymm
******
Production code - Serial number
YY = year of production,
mm = month of production
PIN
Product Information Number
Data related to Domestic Hot Water
Data related to Central Heating
Information regarding electrical power supply
(Voltage, mains frequency, elmax, IP-class)
PMS
Permissible overpressure in CH circuit in bar
PWS
Permissible overpressure in DHW circuit in bar
Qn HS
Input related to gross caloric value in kilowatts
Qn Hi
Input related to net caloric value in kilowatts
Pn
Output in kilowatts
BE, CH, DE, ES,
FR, GB, IE, IT, MT
Countries of Destination (EN 437)
I2E(s), I2H,
IIELL3P, II2H3P,
II2Esi3P
Approved unit categories (EN 437)
G20-20 mbar
G31-37 mbar
Gas group and gas connection pressure as set
at the factory (EN 437)
B23, ......C93(x)
Approved flue gas category (EN 15502)
Tmax
Maximum flow temperature in °C
IPX4D
Electrical protection class
Identification of the product
You will find the unit details on the data plate on the bottom
of the boiler. The data plate contains, important information
and the boiler specification (boiler type and model name), and
the serial number: