FX-3R Maintenance Guide
1-8
1-3. Replacing the Cable Bear
1-3-1. Replacing the X-Axis Cable Bear
(1) Remove the screws and hexagon nuts fixing the X-cable bear.
(2) Open the flap of the X-cable bear, disconnect the cables, and replace the cable bear.
(3) Apply the grease evenly to four surfaces inside the cable bear.
(The reference applying amount is that whitish grease can be checked.)
(4) Reassemble the parts and components in the reverse order of disassembly. At this time, pay
special attention so that
any cables are not entangled inside the cable bear.
∗ After the grease has been applied, check the cables in the cable bear. When necessary, apply
the grease again.
GERALYN grease (MGREAS400GA)
SL3061232TN
Washer assembled
round screw, M6 × 12
NM6060001SC
Hexagon nut M6
40046786
X-cable bear
Figure 1-3-1-1 X-Axis Cable Bear
Rev. 1.00