FX-3R Maintenance Guide
5-11
Rev. 1.00
5-7. Replacing the Support Table Home Position Sensor
(BU Home Position Sensor)
1) Detach the sensor from the sensor bracket.
2) Adjust the distance between the sensor and sensor dog to 1 mm.
Figure 5-7-1 BU Home Position Sensor
5-8. Replacing the T-PIN Sensor (Optional)
1) Remove the adjustment screw to detach the sensor bracket and replace the sensor.
When reassembling the components, adjust the position of the sensor bracket by loosening the
adjustment screw and moving the sensor bracket up and down so that the T-PIN sensor is
turned ON when the center ring pin is lowered by 1.5
0
-0.5
mm.
2) Carefully handle the cables.
Figure 5-8-1 T-PIN Sensor
40046962
BU sensor bracket
40002124
Backup table home
position sensor assembly
For tie-band
Screw supplied
with sensor
SL6030692TN
SEMS cap bolt with washer
M3×6
40002122
T-PIN sensor assembly