FX-3R Maintenance Guide
8-16
8-3-4. Replacing the Connector Cable
1) Remove the connector mounting screws to detach the connector from the FDC bracket.
2) Detach the front panel. (See Figure 8-3-3.)
3) Disconnect the connectors from the electric bank PCB and replace the cables.
4) Reassemble the components in the reverse order of disassembly.
40084636
FDC bracket
40084826 - EF IF CBL 1-5 ASM
40084827 - EF IF CBL 6-10 ASM
40084828 - EF IF CBL 11-15 ASM
40084829 - EF IF CBL 16-20 ASM
40084830 - EF IF CBL 21-25 ASM
40084831 - EF IF CBL 26-30 ASM
HK079190000
Connector screw
Figure 8-3-4-1 Replacement of Connector Cable