FX-3R Maintenance Guide
8-17
8-3-5. Replacing the Connector for Off-line Setup
1) Disconnect the connector for the off-line setup from the E trolley cover R.
2) Disconnect the connector connecting the cable of the connector for the off-line setup and the
relay cable to the electric bank PCB. After that, replace the connector for the off-line setup.
3) Reassemble the components in the reverse order of disassembly.
Rev. 1.00
40084841
EF setup cable 1 bracket
assembly
40084837
EF setup cable 2
assembly
40084841
EF setup cable 1 bracket
assembly
Connected at fixing base
40084666
E trolley cover R
Figure 8-3-5-1 Replacement of Connector for Off-line Setup