FX-3R Maintenance Guide
1-9
1-3-2. Replacing the Y-Axis Cable Bear
(1) Remove the screws and hexagon nuts fixing the Y-cable bear.
(2) Open the flap of the Y-cable bear, disconnect the cables, and replace the cable bear.
(3) Apply the grease evenly to four surfaces inside the cable bear.
(The reference applying amount is that whitish grease can be checked.)
(4) Reassemble the parts and components in the reverse order of disassembly. At this time, pay
special attention so that
any cables are not entangled inside the cable bear.
∗ After the grease has been applied, check the cables in the cable bear. When necessary, apply
the grease again.
GERALYN grease (MGREAS400GA)
40046709
Y-cable bear
SL6061292TN
SEMS cap bolt with washer M6 × 12
Figure 1-3-2-1 Y-Axis Cable Bear
Rev. 1.00