Section
5: Introduction to TSP operation Series 2600B System SourceMeter® Instrument
Reference Manual
5-22 2600BS-901-01 Rev. B / May 2013
KIPulse tag parameter pulse functions
ConfigPulseIMeasureV() (on page 7-33)
ConfigPulseIMeasureVSweepLin() (on page 7-35)
ConfigPulseIMeasureVSweepLog() (on page 7-37)
ConfigPulseVMeasureISweepLin() (on page 7-41)
ConfigPulseVMeasureI() (on page 7-39)
ConfigPulseVMeasureISweepLog() (on page 7-43)
InitiatePulseTest() (on page 7-103)
InitiatePulseTestDual() (on page 7-104)
QueryPulseConfig() (on page 7-158)
KIPulse simple pulse functions
PulseIMeasureV() (on page 7-156)
PulseVMeasureI() (on page 7-157)
Advanced features for KIPulse tag parameter pulse functions
Variable off time between pulses in a pulse train
The KIPulse “Configure” functions will accept the toff parameter as a table, or as a number. The
table allows you to define different off times to be used after each pulse. The following should be
noted:
If toff is passed as a number or only a single value is used in the table, it will be used for all
points in a multiple point pulse.
The number of times specified in the table must match the number of points called for in the
sweep.
The times used in tables must match for dual channel pulsing.
Each specified off time must adhere to the duty cycle limits for the specified pulsing region.
Simultaneous IV measurement during pulse
The KIPulse “Configure” functions will optionally accept an extra reading buffer to activate
simultaneous IV measurements during pulsing. Previous usage of passing in a reading buffer or a nil
(for no measurement) is still supported.
KIHighC factory script
The KIHighC factory script is made up of two functions: i_leakage_measure() and
i_leakage_threshold(). These functions are intended to be used when HighC mode is active.
Output is generally at a non-zero voltage prior to calling these functions. These functions can also be
used to step the voltage to zero volts in order to measure the leakage current.
i_leakage_measure() (on page 7-101)
i_leakage_threshold() (on page 7-102)
KIParlib factory script
The KIParlib factory script is made up of two functions: gm_vsweep() and gm_isweep().
gm_vsweep() (on page 7-99)
gm_isweep() (on page 7-98)

Table of Contents

Other manuals for Keithley 2614B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2614B and is the answer not in the manual?

Keithley 2614B Specifications

General IconGeneral
BrandKeithley
Model2614B
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals