GENERAL
L3560, L4060, L4760, L5060, L5460, L6060, WSM
G-4
3. HANDLING PRECAUTIONS FOR ELECTRICAL
PARTS AND WIRING
To ensure safety and prevent damage to the machine and
surrounding equipment, obey the following precautions in handling
electrical parts and wiring.
• Check electrical wiring for damage and loosened
connection every year. To this end, educate the customer
to do his or her own check and at the same time
recommend the dealer to perform periodic check for a fee.
• Do not try to modify or remodel any electrical parts and
wiring.
• When removing the battery cables, disconnect the negative
cable first. When installing the battery cables, connect the
positive cable first.
WSM000001GEG0062US0
[1] WIRING
• After installing wiring, check protection of terminals and
clamped condition of wiring.
WSM000001GEG0070US0
• Securely tighten wiring terminals.
WSM000001GEG0063US0
• Do not let wiring contact dangerous part.
WSM000001GEG0064US0
(1) Negative Terminal (2) Positive Terminal
(1) Cover
(Securely Install Cover)
(1) Correct
(Securely Tighten)
(2) Incorrect
(Loosening Leads to damaged
Contact)
(1) Dangerous Part (Sharp Edge)
(2) Wiring (Incorrect)
(3) Wiring (Correct)
(4) Dangerous Part