CABIN
L3560, L4060, L4760, L5060, L5460, L6060, WSM
10-S28
(6) Recirculation / Fresh Air Motor Checking
Recirculation / Fresh Air Motor Checking
1. Remove the outer roof.
2. Make sure that the recirculation / fresh air selection switch is
functioning.
3. Turn the main switch to "ON" position.
4. Turn the blower switch (3) to "1" position.
5. Push the recirculation / fresh air selection switch (2) and make
sure that the switch is at "Recirculation" position.
6. If the motor does not run, replace it.
9Y1210824CAS0060US0
(7) Blower Relay
Blower Relay Checking
1. Remove the outer roof (1).
2. Remove the blower relay (2).
3. Apply battery voltage across terminals 1 and 2, and check for
continuity across terminals 3 and 4.
4. If continuity is not established, across the terminal 3 and 4,
replace it.
9Y1210824CAS0061US0
(1) Recirculation / Fresh Air Motor
(2) Recirculation / Fresh Air Selection
Switch
(3) Blower Switch
(1) Outer Roof
(2) Blower Relay
(3) Connector (Relay)
(4) Battery