ELECTRICAL SYSTEM
L3560, L4060, L4760, L5060, L5460, L6060, WSM
9-S33
[5] ECU CONTROL SYSTEM
(1) Checking Fuse and Connector
Checking Fuse
1. The tractor electrical system is protected from potential damage
by fuses.
A blown fuse indicates that there is an overload or short
somewhere in the electrical system.
2. If any of the fuses should blow, replace with a new one of the
same capacity.
• Before replacing a blown fuse, determine why the fuse blew
and make any necessary repairs. Failure to follow this
procedure may result in serious damage to the tractor
electrical system.
If any of them should blow, replace with a new one of the
same capacity.
Protected Circuit
9Y1210824ELS0025US0
Fuse
No.
Capacity
(A)
Protected circuit ROPS CABIN
1 5 Meter (Battery)
2
15 Hazard –
20 Hazard –
3 5 Transmission controller (Battery)
4 10 Radio (Battery) –
5 20 Air conditioner blower –
6 20 Engine ECU (Battery)
7 30 Starter relay
8 5 Engine ECU (IG)
9 20 Cigar lighter –
10 5 Radio (ACC) –
11 15 Transmission controller (IG)
12 10 Meter (IG)
13 5 Meter switch
14 30 Head lights
15 7.5 Air conditioner compressor –
16 30 Wiper –
17 15 Flasher –
18
10 Work light –
15 Work light –
[A] ROPS Type [B] CABIN Type