Commissioning
Holding brake configuration
6
111
EDBCSXA064 EN 3.2
6.7 Holding brake configuration
Tip!
If you use a motor without a holding brake, you can skip this chapter.
In GDC, you can find the parameters and codes to be set in the parameter menu under
Complete code list.
Code Name Description
C0472/10 FCODE analog [%] Speed threshold from which the drive is allowed to output the signal "Close
brake".
l This code refers to the maximum speed set in C0011.
Note: Enter a value > 0 so that the brake can be opened.
C0472/11 FCODE analog [%] Value/direction of the torque against the holding brake.