AIF interface (X1) configuration
Synchronisation
XCAN sync response
9
190
EDBCSXA064 EN 3.2
9.6 Synchronisation
9.6.1 XCAN sync response
The response to the receipt of a sync telegram can be configured via C2375:
Code Possible settings IMPORTANT
No. Designation Lenze/ap
pl.
Selection
C2375 TX mode for XCANx_OUT
(AIF interface X1)
1 XCAN Tx
mode
0 Response to sync XCAN1_OUT
2 XCAN Tx
mode
0 Response to sync XCAN2_OUT
3 XCAN Tx
mode
0 Response to sync XCAN3_OUT
0 Response to sync
1 No response to sync
2 Event
3 Event, cycle C2356 superimposed
9.6.2 XCAN sync identifier
The transmit and receive identifiers of the sync telegram can be configured via
C2367/C2368:
Code Possible settings IMPORTANT
No. Designation Lenze/ap
pl.
Selection
C2367 Sync Rx Id 128
XCAN receive identifier of the
sync telegram
(AIF interface X1)
1 {1} 2047
C2368 Sync Tx Id 128
XCAN send identifier of the sync
telegram
(AIF interface X1)
1 {1} 2047
C2369 0
XCAN Consumer Heartbeat
COB−ID
(AIF interface X1)
0 {1} 255

Table of Contents

Other manuals for Lenze ECSxK001 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze ECSxK001 series and is the answer not in the manual?

Lenze ECSxK001 series Specifications

General IconGeneral
BrandLenze
ModelECSxK001 series
CategoryControl Unit
LanguageEnglish

Related product manuals