EasyManuals Logo
Home>Lenze>Control Unit>ECSxK001 series

Lenze ECSxK001 series User Manual

Lenze ECSxK001 series
483 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #380 background imageLoading...
Page #380 background image
Appendix
Memories
Temporary codes
14
380
EDBCSXA064 EN 3.2
E4 00 0A 00 01 00 00 00 1C FF 00 00
wSizeHeader = 00 E4 = 228 Bytehex
wDataType = 00 0A = 10 (Cam data)hex
dwVersion =00000001hex
dwRealSize = 00 00 FF 1C = 65308 Bytehex
ECSXA295
Fig. 14−1 Header interpretation
14.3.4 Temporary codes
The codes C2500 and C2501 are temporary codes, i. e. the data of these codes
ƒ does not assign storage space in the EPROM of the drive.
ƒ cannot be stored with C0003 = 1 in the parameter set of the drive.
ƒ is lost after switch−off of the drive or after mains failure.
ƒ is fixedly interlinked with the flag area of the PLC.
Tip!
ƒ Temporary codes are suited for the reception of parameters which are to be
accessed during a switch−on cycle of the ECSxA... axis module only.
ƒ Furthermore, the codes present the possibility to directly (e.g. via HMI)
access the flag area of the ECSxA... axis module without having to apply a
variable.
Code Possible settings IMPORTANT
No. Designation Lenze/
{Appl.}
Selection
C2500
PLC flag 1 ... 255
380
0 {1} 65535
C2501
PLC flag 256 ... 512
380
0 {1} 65535

Table of Contents

Other manuals for Lenze ECSxK001 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze ECSxK001 series and is the answer not in the manual?

Lenze ECSxK001 series Specifications

General IconGeneral
BrandLenze
ModelECSxK001 series
CategoryControl Unit
LanguageEnglish

Related product manuals