Monitoring functions
Configuring monitoring functions
Function monitoring of thermal sensors (H10, H11)
10
210
EDBCSXA064 EN 3.2
10.3.8 Function monitoring of thermal sensors (H10, H11)
The function of the thermal sensors of the heatsink and the interior of the device is
monitored. If the thermal sensors report values outside the measuring range, fault H10
(heatsink) or H11 (interior) is reported. The response to these faults can be defined under
C0588.
Code Possible settings IMPORTANT
No. Designation Lenze/
{Appl.}
Selection
C0588 MONIT
H10/H11
0
Fault response − monitoring
Thermal sensors in the
controller.
H10: Sensor inside the device
H11: Heatsink sensor
210
0 TRIP
2 Warning
3 Off