System modules
DFOUT_IO_DigitalFrequency (node number 22)
Inputs_DFOUT / Outputs_DFOUT
13
338
EDBCSXA064 EN 3.2
13.17 DFOUT_IO_DigitalFrequency (node number 22)
13.17.1 Inputs_DFOUT / Outputs_DFOUT
This SB converts internal speed signals into frequency signals and outputs them to X8
(configuration via C0491).
ƒ Transmission is effected with high precision (without offset and amplification
faults) including remainder considered.
ƒ The type of output signals can be set via C0540.
ƒ A configuration of the master frequency output X8 as input ( 331) is possible via
C0491.
DFOUT_IO_DigitalFrequency
X8
C0540
0
1
2
CTRL
C0549
C0545
C0030C0540
0
1
2
n
max
15000 rpm
0
0
1
1
X7
C0491
C0547
DFOUT_nOut_v
DFOUT_nIn_v
ECSXA232
Fig. 13−25 System block "DFOUT_IO_DigitalFrequency"
Note!
The process image is recreated for every task the SB is used in.
ƒ If therefore DFOUT_nIn_v and DFOUT_nOut_v are used in several tasks, an
individual process image of the SB is created for each of these tasks.
ƒ This process is different from the previous process image principle!
System variables
Variable Data
type
Signal
type
Address Display
code
Display
format
Notes
DFOUT_nOut_v Integer Velocity %QW22.0
C0547
dec
[%]
C0549
dec
[rpm]
DFOUT_nIn_v Integer Velocity %IW22.0 ˘ ˘

Table of Contents

Other manuals for Lenze ECSxK001 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze ECSxK001 series and is the answer not in the manual?

Lenze ECSxK001 series Specifications

General IconGeneral
BrandLenze
ModelECSxK001 series
CategoryControl Unit
LanguageEnglish

Related product manuals