Driving modes
6.5 Installing/removing the outrigger beams
6 - 38 3 302 690 en Operating manual
GMK4100L-1
23.11.2017
6.5.7 Disconnecting/establishing hydraulic connection
There is a valve block on each outrigger beam. The position of the valve
block may differ from the drawings, depending on the outrigger beam.
Undoing the connection
Always disconnect all connections (4).
• Hold the hose (1) firmly.
• Pull the lock (2) against the stop. The hose is
pushed out of the connection (3).
• Seal all connecting points.
Making the connection
Always establish all connections (4).
The assignment is specified by colour
designations.
• Insert the hose (1) into the connection (3).
• The lock (2) engages.