Crane operation
11.7 Working range limiter
Operating manual 3 302 690 en 11 - 147
GMK4100L-1
23.11.2017
11.7.6 Shutdown by working range limiter
If a limit value is reached, RCL shutdown will occur. All movements that
would go closer to the limit value will be disabled. Shutdown will remain
active even if you switch off the monitoring function.
The
RCL display also shows an information symbol. You must leave the
shutdown area in order to enable the movement.
If you override the RCL, the shutdown will be overridden and all movements
enabled.
RCL display
Shutdown point
reached for
Disabled movements
Overall height
–Raising
–Extension
– Lowering the hoist
– Derricking the
lattice extension
Working radius
– Lowering the boom
–Extension
– Lifting the hoist
– Derricking the lattice extension
Slewing angle A – Slewing to the left
Slewing angle B – Slewing to the right
Rope travel limitation
Lifting
– Lifting
Rope travel limitation
Lowering
–Lowering
G
Risk of accidents due to overriding shutdown procedures
Override RCL only if it is absolutely necessary and you have a clear view of
the hazard area. Bear in mind that, due to the boom bending for example,
the overall height is increased if you set down the load.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK4100L-1 and is the answer not in the manual?

Manitowoc Grove GMK4100L-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK4100L-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals