Malfunctions during crane operation
14.1 Emergency stop switch
Operating manual 3 302 690 en 14 - 1
GMK4100L-1
23.11.2017
14 Malfunctions during crane operation
14.1 Emergency stop switch
• Stop all crane movements.
Four emergency stop switches are provided
for emergencies:
• Press an emergency stop switch (1), (2) or (3).
The switch latches.
The engine shuts down.
After activating an emergency stop switch;
à Resetting the emergency stop switch, p. 4 - 19.
H
The battery master switch cannot be used as an emergency stop switch for
the engine. The engine continues to run after the battery master switch has
been switched off.
G
Risk of overloading if used improperly
Press the emergency stop switch only if it is no longer possible to stop the
crane movements with the normal operating elements.
The emergency stop switch stops the crane movements suddenly. This
may overload the truck crane, e.g. in the event of high working speeds and
large working radii.
1 On the carrier
2 On the hand-held control unit
3 In the crane cab

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK4100L-1 and is the answer not in the manual?

Manitowoc Grove GMK4100L-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK4100L-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals