Malfunctions during crane operation
14.5 Emergency operations and programs
14 - 48 3 302 690 en Operating manual
GMK4100L-1
23.11.2017
Stopping
movements in
emergencies
This section applies only to the situation where a motion does not stop after
releasing the Function button.
• Press the emergency stop switch (1) – the engine switches off.
The switch (1) latches.
After activating an emergency stop switch;
à Resetting the emergency stop
switch
, p. 4 - 19.
Switch off
the engine
You can switch off the engine only by using the hand-held control.
• Stop all crane movements.
• Press the button (1) – the engine will switch off.
14.5.5 Notes on slewing in emergency operation
For the Standard
slewing range
type
If the MAXbase slewing range type is activated; à p. 14 - 50.
Slewing is not monitored by the RCL in emergency operation.
G
Risk of overturning when slewing in emergency operation!
Check the table to see if slewing is permitted. Adhere to the enabled work-
ing range specified in the
lifting capacity table and observe the restrictions
described.
If you have any doubts, contact
Manitowoc Crane Care.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK4100L-1 and is the answer not in the manual?

Manitowoc Grove GMK4100L-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK4100L-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals