PAGE 42 / 80 NXAMPMK2 USER MANUAL
FREQUENCY
Here can be adjusted the frequency at which the impedance measurement will be done for the speaker(s)
connected to the channel selected. The frequency is adjustable from 14500 to 21000 Hz in 1/12 octave
steps.
Most of the time, there is no need to change this frequency if you are using the Internal Generator.
If external pilot tone is used (from the audio program sent to the NXAMPmk2 on its analog or digital inputs),
be sure that the frequency selected here is close as possible to the pilot tone frequency.
LEVEL
The level of the internal HF burst generator can be adjusted here when using the Internal Generator mode.
The level is adjustable from 0 to 5 volts, with 0.5 volts steps. This voltage is intended to be given at the
output of the NXAMPmk2 speakON connectors for the channel selected.
NB: Setting the level to 1 volt is a good start, then adjust the output level to have a stable reading of the
impedance on the screen. Long speaker cable and high impedance speaker(s) connected might need a
higher output voltage. An output voltage too high can lead to sub-harmonic generation that can be audible
at the speaker output.
IMPEDANCE HIGH AND LOW LIMITS
Once the measured impedance is displayed on the screen, you can select low and high limits that will trigger

GPIO port (see GPIO section, to route them to GPIO pins).
NB: These limits should be adjusted with care. External parameters such as cable type and length,
temperature, wind, 
adjust these limits on site in real-life conditions to prevent false triggering of the impedance fault.
MEASURED IMPEDANCE
If the impedance of the connected load is between 0 and 100 Ohm at the measurement frequency, the actual

If the NXAMPmk2 is unable to measure the impedance of the speaker because there is no pilot tone (Internal
generator at 0V or external pilot tone not detected), 
impedance alerts will be raised.

Table of Contents

Other manuals for Nexo NXAMP4x2mk2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nexo NXAMP4x2mk2 and is the answer not in the manual?

Nexo NXAMP4x2mk2 Specifications

General IconGeneral
BrandNexo
ModelNXAMP4x2mk2
CategoryController
LanguageEnglish

Related product manuals