PAGE 74 / 80 NXAMPMK2 USER MANUAL
Below is the full list of any global or per channel information that can be logged into the NXAMPmk2 or
remotely, and if this piece of information can raise an alert.
Mains voltage (in V) measured from the
MAINS 1 or 2 plug at the back of the
NXAMP. MAINS 2 only applies to
NXAMP4x4.
Power Supply 1, 2
Voltage
Output voltage (in V) of the power supply
feeding power amplifier 1 or 2. Power
Supply 2 only applies to NXAMP4x4.
Peak level (in dBFS) at the output of the
analog to digital converter of an analog
input (A to D). Given with an accuracy of
±3dB, and at a maximum rate of 25Hz.
Peak level (in dBFS) of a network (E to H)
input. Given with an accuracy of ±3dB,
and at a maximum rate of 25Hz.
Mute status of the four channels. If
status is preserved.
The amplifier has to reduce its output
level for protection (if too hot). Output
level is reduced by 3dB if one of the
then 3 more dB above 80°C.
The amplifier has to mute its output for
protection (if extremely hot more than
90°C on the heat sink or if a problem
arises on a channel, e.g. DC output
detected or
level.
Protection status of the amplifier. If
protecting, it is reducing or muting one or
several outputs due to malfunctions as
overheating, output DC, or short circuit.
Fan has stopped rotating due to error.
Extension card is overclocking.
Extension card is not ready.
Extension card has audio error.
Input patch has internally switched to
analog because no digital signal could be
detected.
Power Amp Temp.
(per ch.)
Temperature (in °C) of the amplifier for a
channel.