Below is the full list of any global or per channel information that can be logged into the NXAMPmk2 or
remotely, and if this piece of information can raise an alert.
Global/Ch.
Name
Description
Range
Log
Alert
Global
Mains 1, 2 Voltage
Mains voltage (in V) measured from the
MAINS 1 or 2 plug at the back of the
NXAMP. MAINS 2 only applies to
NXAMP4x4.
0.. V
Power Supply 1, 2
Voltage
Output voltage (in V) of the power supply
feeding power amplifier 1 or 2. Power
Supply 2 only applies to NXAMP4x4.
0.. V
Input level (analog)
Peak level (in dBFS) at the output of the
analog to digital converter of an analog
input (A to D). Given with an accuracy of
±3dB, and at a maximum rate of 25Hz.
-60, 0dBFS
Input level (network)
Peak level (in dBFS) of a network (E to H)
input. Given with an accuracy of ±3dB,
and at a maximum rate of 25Hz.
-60, 0 dBFS
Overmute/Global
mute
Mute status of the four channels. If
     
status is preserved.
0, 1
Limiting Output
The amplifier has to reduce its output
level for protection (if too hot). Output
level is reduced by 3dB if one of the

then 3 more dB above 80°C.
0, 1
Muting Output
The amplifier has to mute its output for
protection (if extremely hot more than
90°C on the heat sink or if a problem
arises on a channel, e.g. DC output
detected or    
level.
0, 1
Amp protect
Protection status of the amplifier. If
protecting, it is reducing or muting one or
several outputs due to malfunctions as
overheating, output DC, or short circuit.
0, 1
FAN1, 2, 3 is
Stopped
Fan has stopped rotating due to error.
0, 1
Card overclocking
Extension card is overclocking.
0, 1
Card not ready
Extension card is not ready.
0, 1
Card audio err
Extension card has audio error.
0, 1
Analog fallback
Input patch has internally switched to
analog because no digital signal could be
detected.
0, 1
Per channel
Power Amp Temp.
(per ch.)
Temperature (in °C) of the amplifier for a
channel.
0.. °C

Table of Contents

Other manuals for Nexo NXAMP4x2mk2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nexo NXAMP4x2mk2 and is the answer not in the manual?

Nexo NXAMP4x2mk2 Specifications

General IconGeneral
BrandNexo
ModelNXAMP4x2mk2
CategoryController
LanguageEnglish

Related product manuals