l
[Output]
Object signals:
•
No.20 to 23 pins: Connect the COMOUT1 and COMIN0 terminals when using these signals.
a) Internal specifications for NPN connection
Item Specifications
Internal circuit dia-
gram
COM OUT
COM IN
+
Load
Each output
terminal
b) Internal specifications for PNP connection
Item Specifications
Internal circuit dia-
gram
COM OUT
COM IN
+
Load
Each output
terminal
6-1-4
Other (Parallel Converter Cable)
When you change to connect the F series, FZ5 series, or FZ5-L series to FH series Sensor Controller,
you can convert by using the appropriate parallel converter cable of FH-VPX series under the usable
condition.
Corresponding model
Con-
vertible
Applicable parallel
conversion cable
Required conditions
FZ£ series
Yes FH-VPX-FZ
• RESET is not used.
*1
• The same power supply is shared in
COMIN and COMOUT
.
FZ£-L35£ series
Yes FH-VPX-FZL
• RESET is not used.
*1
F160
series
F160-C10 Yes FH-VPX-F160
• RESET is not used.
*1
• The same power supply is shared in
COMIN and COMOUT
.
• Do not use DI5 and DI6.
F160-C10CP No - -
F160-C10CF No - -
F210
series
F210-C10 Yes FH-VPX-F210
• RESET is not used.
*1
• The same power supply is shared in
COMIN and COMOUT
.
• Do not use DI8 and DI9.
F210-C10-ETN Yes FH-VPX-F210
F500
series
F500-C10 Yes FH-VPX-F210
F250 series No - -
F270 series No - -
*1. If the RESET signal becomes unavailable by conversion even though the signal has been used, but it caus-
es no problem, the conversion is possible by satisfying other required conditions.
6 I/O Interface
6-19
FH Series Vision System Hardware Setup Manual (Z366-E1)
6-1 Parallel Interface
6
6-1-4 Other (Parallel Converter Cable)