Page #251 background imageLoading...
Page #251 background image
Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit Page
E05
Input Terminal [DI5]
Function Selection
0 to 188 normally-open input,
1000 to 1188 normally-close
input
8 -
-
page
7-26
E10
2nd Acceleration Time
1
0.00 to 6000.00 s
6.00
Availa-
ble
s
page
5-39
page
5-43
E11
2nd Deceleration Time
1
0.00 to 6000.00 s
6.00
Availa-
ble
s
page
5-39
page
5-43
E12
1st Acceleration Time
2
0.00 to 6000.00 s
6.00
Availa-
ble
s
page
5-43
E13
1st Deceleration Time
1
0.00 to 6000.00 s
6.00
Availa-
ble
s
page
5-43
E14
2nd Acceleration Time
2
0.00 to 6000.00 s
6.00
Availa-
ble
s
page
5-43
E15
2nd Deceleration Time
2
0.00 to 6000.00 s
6.00
Availa-
ble
s
page
5-43
E16 Torque Limit 3
0 to 300 %
300
Availa-
ble
%
page
6-81
E17 Torque Limit 4
0 to 300 %
300
Availa-
ble
%
page
6-81
E20
Output Terminal [DO1]
Function Selection
0 to 241 normally-open output,
1000 to 1241 normally-close
output
Refer to the manual for the
contents of function assign-
ment.
0 - -
page
7-31
4 Parameter List
4-85
M1 Series Standard Type User's Manual (I669)
4-2 List of Parameters by Group
4
4-2-2 Parameter E (Terminal Functions)

Table of Contents